Cooling Tower Pump


Classification:

In Haoyuan pump industry, customer satisfaction is our pursuit. We not only provide high quality products, but also provide customers with personalized solutions and high-quality after-sales service to ensure that your needs are met.

Request Quote
  • Product Description
    • Commodity name: Cooling Tower Pump

    Model Description

     

    Application

    Water circulation for closed cooling towers and condensers
    Cooling for various unit equipment
    General water supply

     

     

    Material

    Pump body, pump cover: Cast iron
    Impeller: Stainless steel 2Cr13
    Pump shaft: 45# steel (seal position 304)
    Mechanical seal dynamic and static rings: Antimony graphite, silicon carbide
    Bearing: Custom high-temperature grease
    Surface treatment: Electrophoretic paint

     

    Structural Features

    Adopts a direct connection structure, stable operation in the later stage, less vibration noise, and convenient maintenance.
    The impeller and pump body are designed with excellent hydraulic models for higher efficiency.
    Pump body, pump cover, impeller and other castings use coated sand and precision casting processes, with a smooth surface and excellent appearance and quality.
    Cast iron flow parts are fully covered with electrophoretic paint process, greatly reducing the impact of rust on the pump's performance and lifespan.

     

    Motor

    YE3 series ultra-high efficiency three-phase asynchronous motor series. Power and type comply with IEC-Normb
    Type: V1(TQLT) B35(TQWT)
    Power supply: 380V, 50Hz
    Protection level: IP55
    Insulation class: F
    Motor shaft: 45# steel (seal position 304) or stainless steel (2Cr13)
    Temperature: Maximum working environment temperature of the motor is 40°C. If the temperature exceeds 40°C, please reduce the power usage.
    Direction: For vertical pumps, viewed from the motor fan side, the direction is clockwise; for horizontal pumps, viewed from the pump inlet side, the direction is counterclockwise.

     

    Operating Conditions

    Medium: Clean water
    Medium temperature: -10°C to 80°C
    Ambient temperature: ≤40°C (altitude less than 1000m, relative humidity not exceeding 95%)
    Maximum working pressure: <0.6MPa

     

    Structure diagram of HYLT vertical cooling tower special pump

     

    Structure diagram of HYWT horizontal cooling tower special pump

     

    Structure diagram of HYLT vertical cooling tower special pump

    Model Power
    (kW)
    Caliber
    (mm/inch)
    Flow
    (m3/h)
    Head
    (m)
    Speed
    (r/min)
    HYLT 50-18-0.75-2 0.75 50/2 inch 18 5 2900
    HYLT 65-28-0.75-2 0.75 65/2.5 inch 28 4 2900
    HYLT 80-53-1.1-2 1.1 80/3 inch 53 4 2900
    HYLT 80-70-1.5-2 1.5 80/3 inch 70 4 2900
    HYLT 80-84-2.2-2 2.2 80/3 inch 84 4 2900
    HYLT 100-100-2.2-4 2.2 100/4 inch 100 5 1470
    HYLT 125-150-3-4 3 125/5 inch 150 5 1470
    HYLT 125-180-4-4 4 125/5 inch 180 5 1470
    HYLT 150-230-5.5-4 5.5 150/6 inch 230 5 1470
    HYLT150-286-7.5-4 7.5 150/6 inch 286 5 1470
    HYLT 200-336-11-4 11 200/8 inch 336 5 1470
    HYLT 200-500-15-4 15 200/8 inch 500 5 1470
    HYLT 250-700-22-4 22 250/10 inch 700 5 1470

     

    HYWT horizontal cooling tower pump performance parameters

    Model Power
    (kW)
    Caliber
    (mm/inch)
    Flow
    (m3/h)
    Head
    (m)
    Speed
    (r/min)
    HYWT 50-18-0.75-2 0.75 50/2 inch 18 5 2900
    HYWT 65-28-0.75-2 0.75 65/2.5 inch 28 4 2900
    HYWT 80-53-1.1-2 1.1 80/3 inch 53 4 2900
    HYWT 80-70-1.5-2 1.5 80/3 inch 70 4 2900
    HYWT 80-84-2.2-2 2.2 80/3 inch 84 4 2900
    HYWT 100-100-2.2-4 2.2 100/4 inch 100 5 1470
    HYWT 125-150-3-4 3 125/5 inch 150 5 1470
    HYWT 125-180-4-4 4 125/5 inch 180 5 1470
    HYWT 150-230-5.5-4 5.5 150/6 inch 230 5 1470
    HYWT150-286-7.5-4 7.5 150/6 inch 286 5 1470
    HYWT 200-336-11-4 11 200/8 inch 336 5 1470
    HYWT 200-500-15-4 15 200/8 inch 500 5 1470
    HYWT 250-700-22-4 22 250/10 inch 700 5 1470

    Note: The entire series uses 304 stainless steel impellers and stainless steel shafts.

     

    Import and Export Flange Dimensions GB/T17241.6-2008

    DN Pressure Level D D1 D2 n-d0
    50 PN10 165 125 102 4-18
    65 PN10 185 145 122 4-18
    80 PN10 200 160 133 8-18
    100 PN10 220 180 158 8-18
    125 PN10 250 210 184 8-18
    150 PN10 285 240 212 8-23
    200 PN10 340 295 268 8-23
    250 PN10 395 350 320 12-23
    250 PN10 375 335 312 12-19

     

    HYLT Vertical Cooling Tower Pump Installation Dimension Table

     

    Model Pressure Level DN LO m a L1 b1 b2 L2 b C
    mm
    HYLT 50-18-0.75-2 PN10 50 300 150 90 350 83 190 280 135 165
    HYLT 65-28-0.75-2 PN10 65 345 170 100 360 93 200 325 155 185
    HYLT 80-53-1.1-2 PN10 80 400 180 112 380 100 225 375 158 200
    HYLT 80-70-1.5-2 PN10 80 400 180 112 425 100 235 375 158 200
    HYLT 80-84-2.2-2 PN10 80 400 180 112 485 100 235 375 158 200

     

     HYLT Vertical Cooling Tower Pump Installation Dimension Table

    Type Pressure Level DN L0 m a L 1 b1 b2 f e d
    mm
    HYLT 100-100-2.2-4 PN10 100 560 280 150 485 135 330 240 200 18
    HYLT 125-150-3-4 PN10 125 570 280 170 480 145 350 240 200 18
    HYLT 125-180-4-4 PN10 125 570 280 170 520 145 350 240 200 18
    HYLT 150-230-5.5-4 PN10 150 690 320 200 560 180 430 240 200 18
    HYLT150-286-7.5-4 PN10 150 730 360 200 610 180 410 300 260 18
    HYLT 200-336-11-4 PN10 200 920 450 270 710 215 510 360 320 18
    HYLT 200-500-15-4 PN10 200 920 450 270 730 215 510 360 320 18
    HYLT 250-700-22-4 PN6 250 950 450 305 810 230 550 360 400 18

     

    HYWT Horizontal Cooling Tower Pump Installation Dimension Table

    Type Pressure
    Grade
    Overall Dimensions Installation Dimensions DN
    L H2 b1 4-d0 a b L1 B1 L2 B2 H H1 A
    HYWT 50-18-0.75-2 PN10 425 245 270 4-12 90 75 100 200 140 224 210 100 162 50
    HYWT 65-28-0.75-2 PN10 450 260 285 4-12 100 78 100 200 140 224 240 120 166 65
    HYWT 80-53-1.1-2 PN10 475 265 315 4-12 110 99 95 200 140 224 270 130 178 80
    HYWT 80-70-1.5-2 PN10 520 280 319 4-12 110 99 95 210 165 240 270 130 184 80
    HYWT 80-84-2.2-2 PN10 540 280 319 4-12 110 99 120 210 190 240 270 130 184 80
    HYWT 100-100-2.2-4 PN10 600 350 390 4-12 120 140 140 250 180 280 380 180 201 100
    HYWT 125-150-3-4 PN10 650 370 415 4-15 135 146 172 250 222 280 417 197 195 125
    HYWT 125-180-4-4 PN10 660 390 431 4-15 135 146 172 280 222 320 417 197 202 125
    HYWT 150-230-5.5-4 PN10 710 450 487 4-15 150 162 180 317 240 365 462 232 224 150
    HYWT150-286-7.5-4 PN10 740 450 487 4-15 150 162 180 317 265 365 462 232 248 150

     

    HYWT Horizontal Cooling Tower Pump Installation Dimension Table

    Type Pressure
    Grade
    Overall Dimensions Installation Dimensions DN
    L H2 b1 4-d0 a b L1 B1 L2 B2 H H1 A
    HYWT 200-336-11-4 PN10 880 620 700 4-22 170 220 700 620 950 675 640 360 0 200
    HYWT 200-500-15-4 PN10 910 620 700 4-22 170 220 700 620 950 675 640 360 0 200
    HYWT 250-700-22-4 PN10 1020 680 740 4-22 190 230 700 620 950 675 700 400 0 250

Keywords: permanent magnet variable frequency water supply unit permanent magnet water-cooled drip irrigation centrifugal pump

Prev

Next

Product inquiry

Filling in your phone and email information will help us to contact you in a timely manner and solve your problems as soon as possible.

Welcome to visit Haoyuan Pump Technology Co., Ltd. official website

If you are interested in our products and services, please contact us and we will be happy to serve you


Company Address:

Xiwan Industrial Zone, Zeguo Town, Wenling City, Zhejiang Province

National Hotline:400-600-5833/189-9926-5888
E-mail:info@haoyuanpump.com
 


Powered by www.300.cn

Business License